| jxlh 回复于:2003-02-14 10:30:53 |
| 去IBM的网站下载这个机型的微码,然后通过串口来升级。 |
| mrcenter 回复于:2003-02-14 11:51:33 |
| 你说的升级是升级系统板吧。是否还有其他的比方说ssa卡,硬盘的微码也要升级那?
能否说明白些。 谢谢。 |
| hsldj2000 回复于:2003-02-14 11:53:32 |
| instfix -ik |grep ML |
| johnsons 回复于:2003-02-14 14:42:03 |
| to jxlh:微码如何通过串口升级?
to hsldj2000:instfix -ik|grep ML应该是instfix -i|grep ML,但是这个和系统微码是两码事。 |
| lljj 回复于:2003-02-14 14:43:43 |
| [quote:47f2544306="hsldj2000"]instfix -ik |grep ML[/quote:47f2544306]
这个是AIX的补丁!不是系统微码! |
| lljj 回复于:2003-02-14 14:46:10 |
| 关于升级微码!我以前自己写了一个!你去久版看看! |
| jxlh 回复于:2003-02-14 14:46:24 |
| 是补丁,不是微码。 |
| 老农a 回复于:2003-02-14 14:48:15 |
| 升级微码下载处都有详细的介绍和说明。
不是通过串口,很简单的。 |
| ibm6000 回复于:2003-02-14 14:54:40 |
| 1,lscfg -vp | grep -F .CL
2, mkdir /tmp/fwupdate make sure it is empty before proceeding 3, cd /tmp/fwupdate chmod +x 7025F80F.BIN ./7025F80F.BIN 目录下增加CL011206.img ReadMe.TXT 4,sum CL011206.img The output will look like this -------> 56006 3158 CL011206.img The checksum is --------------> 56006 5,cd /usr/lpp/diagnostics/bin ./update_flash -f /tmp/fwupdate/CL011206.img The checkpoints 99FF and 99FD alternately appear while the update is in progress 6,Updating with the Diagnostics Service Aid a) Invoke the Service Aids from either on-line or standalone diagnostics. b) Choose Update System or Service Processor Flash. c) Select 'File System' as the source of the flash update image file. The fully qualified path name of the update file is /tmp/fwupdate /CL011206.img d) Press 'F7' key to 'Commit' the update 7,确认升级成功 |
| jxlh 回复于:2003-02-14 15:25:21 |
| 如果你的机器启动不了,你怎么在AIX下升级呢? |
| johnsons 回复于:2003-02-14 15:31:30 |
| SMS |
| ibm6000 回复于:2003-02-14 16:32:33 |
| 进串口升微码,或用软驱(微码损坏时) |
| johnsons 回复于:2003-02-14 16:39:16 |
| ibm6000,能否详细说说如何进串口升微码,或者在那一份资料上?不吝赐教。。。。 |
| ibm6000 回复于:2003-02-14 17:05:30 |
| 好像user guide上有 |
| mrcenter 回复于:2003-02-17 09:10:39 |
| 大家好,谢谢大家踊跃的讨论了!
我找到了相关的连接的,但是我还是需要知道是否所有的部件都要升级? 那位朋友能将问题给整理一下! http://techsupport.services.ibm.com/server/mdownload/download.html 谢谢。 mrcenter |
| jntsg 回复于:2003-02-17 09:30:56 |
| [quote:da90d13b34="johnsons"]ibm6000,能否详细说说如何进串口升微码,或者在那一份资料上?不吝赐教。。。。[/quote:da90d13b34]
6.3 Using the Service Processor Menu Method Service Processor Menus allow updating from diskettes only. Note: All firmware (System, Service Processor and SPCN) will be updated when using this method. Note: Aclearcase/" target="_blank" >ccess to the Service Processor Menus is not available on serial port (S4). a. Power on or shutdown and restart the system. b. When the operator panel on the server says OK, press Enter, to bring up the Service Processor Menu. c. Choose 1 for Service Processor Setup Menu. <Enter> d. Choose 7 for Reprogram Flash EPROM Menu. <Enter> e. Type y to continue. <Enter> f. Follow on-screen update steps as they are presented. g. The 'Rebooting Service Processor ' message appears on the screen. h. Begin watching the operator panel. i. When the panel says 'OK', press Enter. The Service Processor Menu appears on your screen. The second line of the title, Version: CM020916, should match the firmware level you just installed. j. To restart AIX, choose 2 for System Power Control Menu. <Enter> k. Choose 4 for Power-On System. <Enter> l. Type y to confirm. <Enter> If you confirm, the server will reboot and return to the AIX prompt. This may take ten to thirty minutes (or more), depending on the configuration of your target server. Since the update occurs during this shutdown/reboot sequence, it is important to protect the server from interruptions. The checkpoints 99FF and 99FD alternately appear while the update is in progress. Don't forget to retrieve and file any firmware update diskette that may still be in the system's diskette drive. A good time to do this is after the reboot has completed. Your firmware update is complete. |
| mrcenter 回复于:2003-02-17 10:37:28 |
| 楼上的你好。你说的是否对所有的硬件的微码都好用那?
谢谢!!! |
| johnsons 回复于:2003-02-17 11:10:43 |
| 楼上的兄弟说的是通过sp菜单进行SP Firmware的升级,仅此而已,不是对所有的硬件都有效。 |
| david5337 回复于:2003-09-22 08:39:18 |
| 好资料!
找台机器试一下! |
| xxhk 回复于:2003-09-23 19:18:37 |
| 微码升级步骤
1.用lscfg -vp | grep -p alterable 看看你的微码。高档的机型一般有两块微码。 2.下载相关机型最新的微码,一般为bin文件,建议下在unix版的机器上。http://techsupport.services.ibm.com/server/mdownload2/download.html 3.FTP到要刷新的机器上,以下以S85为例,建议ftp是先用bin来二进制传输,然后chmod +x 7017S8xF.BIN 。 4. ./7017S8xF.BIN.解压密码是**RS\6000**.得到三个文件S8xU5.img ,promote.img,ReadMe.TXT.5.校验文件,sum S8xU5.img得到的值,要和网上的比较一下,这一步很重要,千万别错,一般错误,都是没有用二进制传输。6.cd /usr/lpp/diagnostics/bin./update_flash -f /tmp/S8xU5.img开始刷新。 7.重启动,在用lscfg -vp | grep -p alterable 看看微码变了吗? 8.等过几个月使用没问题了,再用promote.img把两块微码刷成一样。具体办法是用老微码启动再刷新了。 |